Loading...
Thumbnail Image
Item

Dose-response mapping of bladder and rectum in prostate cancer patients undergoing radiotherapy with and without baseline toxicity correction

Puri, T.
Rancati, T.
Seibold, P.
Webb, A.
Osorio, E. V.
Green, A.
Gioscio, E.
Azria, D.
Farcy-Jacquet, M. P.
Chang-Claude, J.
... show 10 more
Citations
Google Scholar:
Altmetric:
Abstract
BACKGROUND AND PURPOSE: Radiotherapy dose-response maps (DRM) combine dose-surface maps (DSM) and toxicity outcomes to identify high-risk subregions in organ-at-risk. This study assesses the impact of baseline toxicity correction on the identification of high-risk subregions in dose-response modeling for prostate cancer patients undergoing radiotherapy. MATERIALS AND METHODS: The analysis included 1808 datasets, with 589 exclusions before toxicity-specific data removal. Bladder/rectum were automatically segmented on planning computed tomography scans, DSMs unwrapped into 91x90 voxel grids, and converted to equivalent doses in 2 Gy fractions (EQD2; α/β = 1 Gy). Seventeen late toxicities were assessed with two methods: (i) baseline toxicity subtracted from the maximum of 12- and 24-months toxicity scores, dichotomized at grade 1, and (ii) maximum of 12- and 24-months toxicity scores dichotomized at grade 1. DSMs were split accordingly, and voxel-wise t-values computed using Welch's t-equation. Statistically significant voxels were identified via the 95th percentile of maximum of t-value (Tmax) distribution. RESULTS: Event counts with baseline correction were 82/82/286/226 for urinary tract obstruction/retention/urgency/incontinence, respectively; without baseline correction, they were 93/104/465/361. For bladder DSMs, urinary incontinence, obstruction, retention, and urgency had 1143/186, 1768/1848, 516/0, and 33/0 significant voxels without/with baseline correction. For rectum DSMs, urinary incontinence and tract obstruction had 604/0 and 1980/889 significant voxels without/with baseline correction. However, no significant associations between rectal DSMs and rectum-related toxicities were found. CONCLUSIONS: DRM without baseline correction appears more sensitive to high-risk subregions due to higher event counts. Non-linear toxicity grading and multivariable analysis may enhance DRM reliability.
Description
Date
2025
Publisher
Keywords
Type
Article
Citation
Puri T, Rancati T, Seibold P, Webb A, Osorio EV, Green A, et al. Dose-response mapping of bladder and rectum in prostate cancer patients undergoing radiotherapy with and without baseline toxicity correction. Physics and imaging in radiation oncology. 2025 Jul;35:100805. PubMed PMID: 40687306. Pubmed Central PMCID: PMC12272478. Epub 2025/07/21. eng.
Journal Title
Journal ISSN
Volume Title
Embedded videos