    Quality control aspects of the Philips multileaf collimator.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Authors
    Hounsell, Alan R
    Jordan, Thomas J
    Affiliation
    North Western Medical Physics, Christie Hospital NHS Trust, Manchester, UK.
    Issue Date
    1997-12
    
    Metadata
    Show full item record
    Abstract
    BACKGROUND AND PURPOSE: Linear accelerators equipped with multileaf collimators (MLCs) are becoming more common and are widely available from most commercial manufacturers. There is a need to ensure they retain their commissioning specification using a preventative maintenance and quality control (QC) programme. This paper considers the design criteria of the Philips MLC which are important to the production of a comprehensive quality control programme. MATERIALS AND METHODS: The specific QC problems related to MLCs are identified as the positional accuracy of the leaves and their relationship to the back-up collimators, leakage considerations, the relationship of X-ray to light field and the influence of gravity on the positioning and leakage characteristics of the leaves. These problems are considered in relation to the general design considerations of the MLC, and methods of performing routine quality control checks are discussed. RESULTS AND CONCLUSIONS: The introduction of MLCs into clinical use results in new QC procedures being developed but it can be concluded that for the Philips MLC only an extra 30 min of QC time is needed per month and that its use has added little to the general down-time of this department.
    Citation
    Quality control aspects of the Philips multileaf collimator. 1997, 45 (3):225-33 Radiother Oncol
    Journal
    Radiotherapy and Oncology
    URI
    http://hdl.handle.net/10541/94681
    DOI
    10.1016/S0167-8140(97)00100-X
    PubMed ID
    9426116
    Type
    Article
    Language
    en
    ISSN
    0167-8140
    ae974a485f413a2113503eed53cd6c53
    10.1016/S0167-8140(97)00100-X
    Scopus Count
    Collections
    All Christie Publications

    entitlement

    Related articles

    • Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration.
    • Authors: Baker SJ, Budgell GJ, MacKay RI
    • Issue date: 2005 Apr 7
    • Multileaf collimator characteristics and reliability requirements for IMRT Elekta system.
    • Authors: Liu C, Simon TA, Fox C, Li J, Palta JR
    • Issue date: 2008
    • Multileaf collimator performance monitoring and improvement using semiautomated quality control testing and statistical process control.
    • Authors: Létourneau D, Wang A, Amin MN, Pearce J, McNiven A, Keller H, Norrlinger B, Jaffray DA
    • Issue date: 2014 Dec
    • IMRT delivery performance with a varian multileaf collimator.
    • Authors: Losasso T
    • Issue date: 2008
    • Leakage of the Siemens 160 MLC multileaf collimator on a dual energy linear accelerator.
    • Authors: Klüter S, Sroka-Perez G, Schubert K, Debus J
    • Issue date: 2011 Jan 21
    DSpace software (copyright © 2002 - 2025)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.