Animation and radiobiological analysis of 3D motion in conformal radiotherapy.
Affiliation
North Western Medical Physics, Christie Hospital NHS Trust, Manchester, UK.Issue Date
1999-07
Metadata
Show full item recordAbstract
PURPOSE: To allow treatment plans to be evaluated against the range of expected organ motion and set up error anticipated during treatment. METHODS: Planning tools have been developed to allow concurrent animation and radiobiological analysis of three dimensional (3D) target and organ motion in conformal radiotherapy. Surfaces fitted to structures outlined on CT studies are projected onto pre-treatment images or onto megavoltage images collected during the patient treatment. Visual simulation of tumour and normal tissue movement is then performed by the application of three dimensional affine transformations, to the selected surface. Concurrent registration of the surface motion with the 3D dose distribution allows calculation of the change in dose to the volume. Realistic patterns of motion can be applied to the structure to simulate inter-fraction motion and set-up error. The biologically effective dose for the structure is calculated for each fraction as the surface moves over the course of the treatment and is used to calculate the normal tissue complication probability (NTCP) or tumour control probability (TCP) for the moving structure. The tool has been used to evaluate conformal therapy plans against set up measurements recorded during patient treatments. NTCP and TCP were calculated for a patient whose set up had been corrected after systematic deviations from plan geometry were measured during treatment, the effect of not making the correction were also assessed. RESULTS: TCP for the moving tumour was reduced if inadequate margins were set for the treatment. Modelling suggests that smaller margins could have been set for the set up corrected during the course of the treatment. The NTCP for the rectum was also higher for the uncorrected set up due to a more rectal tissue falling in the high dose region. CONCLUSION: This approach provides a simple way for clinical users to utilise information incrementally collected throughout the whole of a patient's treatment. In particular it is possible to test the robustness of a patient plan against a range of possible motion patterns. The methods described represent a move from the inspection of static pre-treatment plans to a review of the dynamic treatment.Citation
Animation and radiobiological analysis of 3D motion in conformal radiotherapy. 1999, 52 (1):43-9 Radiother OncolJournal
Radiotherapy and OncologyDOI
10.1016/S0167-8140(99)00081-XPubMed ID
10577685Type
ArticleLanguage
enISSN
0167-8140ae974a485f413a2113503eed53cd6c53
10.1016/S0167-8140(99)00081-X
Scopus Count
Collections
Related articles
- Radiotherapy of prostate cancer with or without intensity modulated beams: a planning comparison.
- Authors: De Meerleer GO, Vakaet LA, De Gersem WR, De Wagter C, De Naeyer B, De Neve W
- Issue date: 2000 Jun 1
- Conformal irradiation of concave-shaped PTVs in the treatment of prostate cancer by simple 1D intensity-modulated beams.
- Authors: Fiorino C, Broggi S, Corletto D, Cattaneo GM, Calandrino R
- Issue date: 2000 Apr
- Computerized design of target margins for treatment uncertainties in conformal radiotherapy.
- Authors: Mageras GS, Fuks Z, Leibel SA, Ling CC, Zelefsky MJ, Kooy HM, van Herk M, Kutcher GJ
- Issue date: 1999 Jan 15
- The use of spatial dose gradients and probability density function to evaluate the effect of internal organ motion for prostate IMRT treatment planning.
- Authors: Jiang R, Barnett RB, Chow JC, Chen JZ
- Issue date: 2007 Mar 7
- The influence of interpatient and intrapatient rectum variation on external beam treatment of prostate cancer.
- Authors: Yan D, Xu B, Lockman D, Kota K, Brabbins DS, Wong J, Martinez AA
- Issue date: 2001 Nov 15