dc.identifier.citationPrediction of scattered dose to the testes in abdominopelvic radiotherapy. 2001, 13 (2):120-5 Clin Oncolen
dc.identifier.issn0936-6555
dc.identifier.pmid11373874
dc.identifier.urihttp://hdl.handle.net/10541/83243
dc.description.abstractRadical abdominal radiotherapy in men runs the risk of impairing their fertility owing to scattered dose to the testes, outside of the treated volume. In patients for whom this is a concern it is important to be able to predict the dose to the testes before treatment in order to determine whether semen cryopreservation should be undertaken and testicular shielding performed during treatment. Measurements have been made on an anthropomorphic phantom to determine the magnitude of these doses for a four-field treatment consisting of an anterior-posterior parallel pair and a lateral parallel pair. A dataset is presented, which, together with a correction for patients size, allows an estimate of testicular dose to be made given only the photon energy, interfield distances and the distance from the testes to the nearest beam edge. Thermoluminescent dosimetry has been carried out in 17 patients to validate the use of the data tables. The results indicate that testicular doses may be estimated with a standard deviation corresponding to 1%-2% of the tumour dose, which is sufficient for the purpose of determining whether fertility is threatened by a planned treatment.
dc.language.isoenen
dc.subjectProstatic Canceren
dc.subjectRectal Canceren
dc.subjectUrinary Bladder Canceren
dc.subject.meshAdult
dc.subject.meshAged
dc.subject.meshHumans
dc.subject.meshMale
dc.subject.meshMiddle Aged
dc.subject.meshPredictive Value of Tests
dc.subject.meshProstatic Neoplasms
dc.subject.meshRadiotherapy Dosage
dc.subject.meshRectal Neoplasms
dc.subject.meshTestis
dc.subject.meshUrinary Bladder Neoplasms
dc.titlePrediction of scattered dose to the testes in abdominopelvic radiotherapy.en
dc.typeArticleen
dc.contributor.departmentChristie Hospital NHS Trust, Manchester, UK.en
dc.identifier.journalClinical Oncologyen
html.description.abstractRadical abdominal radiotherapy in men runs the risk of impairing their fertility owing to scattered dose to the testes, outside of the treated volume. In patients for whom this is a concern it is important to be able to predict the dose to the testes before treatment in order to determine whether semen cryopreservation should be undertaken and testicular shielding performed during treatment. Measurements have been made on an anthropomorphic phantom to determine the magnitude of these doses for a four-field treatment consisting of an anterior-posterior parallel pair and a lateral parallel pair. A dataset is presented, which, together with a correction for patients size, allows an estimate of testicular dose to be made given only the photon energy, interfield distances and the distance from the testes to the nearest beam edge. Thermoluminescent dosimetry has been carried out in 17 patients to validate the use of the data tables. The results indicate that testicular doses may be estimated with a standard deviation corresponding to 1%-2% of the tumour dose, which is sufficient for the purpose of determining whether fertility is threatened by a planned treatment.


This item appears in the following Collection(s)

Show simple item record