    Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Authors
    Moore, Christopher J
    Marchant, Thomas E
    Amer, Ali M
    Affiliation
    North Western Medical Physics, Christie Hospital NHS Trust, Manchester, UK.
    Issue Date
    2006-05-07
    
    Metadata
    Show full item record
    Abstract
    Cone beam CT (CBCT) using a zonal filter is introduced. The aims are reduced concomitant imaging dose to the patient, simultaneous control of body scatter for improved image quality in the tumour target zone and preserved set-up detail for radiotherapy. Aluminium transmission diaphragms added to the CBCT x-ray tube of the Elekta Synergytrade mark linear accelerator produced an unattenuated beam for a central "target zone" and a partially attenuated beam for an outer "set-up zone". Imaging doses and contrast noise ratios (CNR) were measured in a test phantom for transmission diaphragms 12 and 24 mm thick, for 5 and 10 cm long target zones. The effect on automatic registration of zonal CBCT to conventional CT was assessed relative to full-field and lead-collimated images of an anthropomorphic phantom. Doses along the axis of rotation were reduced by up to 50% in both target and set-up zones, and weighted dose (two thirds surface dose plus one third central dose) was reduced by 10-20% for a 10 cm long target zone. CNR increased by up to 15% in zonally filtered CBCT images compared to full-field images. Automatic image registration remained as robust as that with full-field images and was superior to CBCT coned down using lead-collimation. Zonal CBCT significantly reduces imaging dose and is expected to benefit radiotherapy through improved target contrast, required to assess target coverage, and wide-field edge detail, needed for robust automatic measurement of patient set-up error.
    Citation
    Cone beam CT with zonal filters for simultaneous dose reduction, improved target contrast and automated set-up in radiotherapy. 2006, 51 (9):2191-204 Phys Med Biol
    Journal
    Physics in Medicine and Biology
    URI
    http://hdl.handle.net/10541/72524
    DOI
    10.1088/0031-9155/51/9/005
    PubMed ID
    16625035
    Type
    Article
    Language
    en
    ISSN
    0031-9155
    ae974a485f413a2113503eed53cd6c53
    10.1088/0031-9155/51/9/005
    Scopus Count
    Collections
    All Christie Publications

    entitlement

    Related articles

    • Preliminary studies for a CBCT imaging protocol for offline organ motion analysis: registration software validation and CTDI measurements.
    • Authors: Falco MD, Fontanarosa D, Miceli R, Carosi A, Santoni R, D'Andrea M
    • Issue date: 2011 Spring
    • The adaptation of megavoltage cone beam CT for use in standard radiotherapy treatment planning.
    • Authors: Thomas TH, Devakumar D, Purnima S, Ravindran BP
    • Issue date: 2009 Apr 7
    • The effects of field-of-view and patient size on CT numbers from cone-beam computed tomography.
    • Authors: Seet KY, Barghi A, Yartsev S, Van Dyk J
    • Issue date: 2009 Oct 21
    • Phantom and in-vivo measurements of dose exposure by image-guided radiotherapy (IGRT): MV portal images vs. kV portal images vs. cone-beam CT.
    • Authors: Walter C, Boda-Heggemann J, Wertz H, Loeb I, Rahn A, Lohr F, Wenz F
    • Issue date: 2007 Dec
    • Online planning and delivery technique for radiotherapy of spinal metastases using cone-beam CT: image quality and system performance.
    • Authors: Létourneau D, Wong R, Moseley D, Sharpe MB, Ansell S, Gospodarowicz M, Jaffray DA
    • Issue date: 2007 Mar 15
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.