Show simple item record

dc.contributor.authorSamuel, Joanne D
dc.contributor.authorBhatt, Rupesh I
dc.contributor.authorMontague, Richard J
dc.contributor.authorClarke, Noel W
dc.contributor.authorRamani, Vijay A C
dc.date.accessioned2009-07-06T08:41:53Z
dc.date.available2009-07-06T08:41:53Z
dc.date.issued2006-12
dc.identifier.citationThe natural history of postoperative renal function in patients undergoing ileal conduit diversion for cancer measured using serial isotopic glomerular filtration rate and 99m technetium-mercaptoacetyltriglycine renography. 2006, 176 (6 Pt 1):2518-22; discussion 2522 J. Urol.en
dc.identifier.issn0022-5347
dc.identifier.pmid17085147
dc.identifier.doi10.1016/j.juro.2006.07.146
dc.identifier.urihttp://hdl.handle.net/10541/72520
dc.description.abstractPURPOSE: There is little consensus regarding long-term followup of renal function in patients who undergo urinary diversion. We established the usefulness of combined serial isotopic glomerular filtration rate measurement and diuresis renography in the early identification of patients at risk for deterioration of renal function following ileal conduit diversion. MATERIALS AND METHODS: A total of 340 patients with ileal conduit diversion who were followed between 1990 and 2000 were identified. We analyzed data on 178 patients who had more than 4 years of followup. Renal function was assessed by serial estimation of serum creatinine, isotopic glomerular filtration rate and diuresis renographic measurements. RESULTS: Of the patients 52 (29%) demonstrated a worsening glomerular filtration rate. Mean followup +/- SEM was 8.2 +/- 0.4 years (range 4 to 30) and 67% of patients had more than 6 years of followup. In this group we found that hypertension, recurrent urinary sepsis and an initial post-diversion glomerular filtration rate of less than 50 ml per minute per 1.73 m were prevalent risk factors. Hypertension was an independent predictor of a decreased glomerular filtration rate in this group. Of 52 patients with a deteriorating glomerular filtration rate 19 had type II or IIIb curves on followup renography, of whom 13 underwent revision surgery. Renal function subsequently stabilized or improved in this group. CONCLUSIONS: Of patients with an ileal conduit 29% have renal function deterioration in the long term. No surgical cause for glomerular filtration rate deterioration was found in 18%. Important predisposing factors in nonobstructed cases were hypertension, recurrent urinary sepsis and a glomerular filtration rate of less than 50 ml per minute per 1.73 m. Hypertension was an independent predictor of a decreased glomerular filtration rate in the group with worsening glomerular filtration rates. In 11% of patients deterioration was due to upper tract obstruction. This was identifiable using renography and the glomerular filtration rate. A type IIIb curve was an early indicator of obstruction.
dc.language.isoenen
dc.subjectUrinary Bladder Canceren
dc.subject.meshAdult
dc.subject.meshAged
dc.subject.meshAged, 80 and over
dc.subject.meshColonic Neoplasms
dc.subject.meshCreatinine
dc.subject.meshCystectomy
dc.subject.meshGlomerular Filtration Rate
dc.subject.meshHumans
dc.subject.meshKidney
dc.subject.meshMiddle Aged
dc.subject.meshPostoperative Period
dc.subject.meshRadioisotope Renography
dc.subject.meshRadiopharmaceuticals
dc.subject.meshTechnetium Tc 99m Mertiatide
dc.subject.meshUrinary Bladder Neoplasms
dc.subject.meshUrinary Diversion
dc.subject.meshUrologic Diseases
dc.titleThe natural history of postoperative renal function in patients undergoing ileal conduit diversion for cancer measured using serial isotopic glomerular filtration rate and 99m technetium-mercaptoacetyltriglycine renography.en
dc.typeArticleen
dc.contributor.departmentDepartments of Urology, Christie Hospital, Salford, United Kingdom.en
dc.identifier.journalThe Journal of Urologyen
html.description.abstractPURPOSE: There is little consensus regarding long-term followup of renal function in patients who undergo urinary diversion. We established the usefulness of combined serial isotopic glomerular filtration rate measurement and diuresis renography in the early identification of patients at risk for deterioration of renal function following ileal conduit diversion. MATERIALS AND METHODS: A total of 340 patients with ileal conduit diversion who were followed between 1990 and 2000 were identified. We analyzed data on 178 patients who had more than 4 years of followup. Renal function was assessed by serial estimation of serum creatinine, isotopic glomerular filtration rate and diuresis renographic measurements. RESULTS: Of the patients 52 (29%) demonstrated a worsening glomerular filtration rate. Mean followup +/- SEM was 8.2 +/- 0.4 years (range 4 to 30) and 67% of patients had more than 6 years of followup. In this group we found that hypertension, recurrent urinary sepsis and an initial post-diversion glomerular filtration rate of less than 50 ml per minute per 1.73 m were prevalent risk factors. Hypertension was an independent predictor of a decreased glomerular filtration rate in this group. Of 52 patients with a deteriorating glomerular filtration rate 19 had type II or IIIb curves on followup renography, of whom 13 underwent revision surgery. Renal function subsequently stabilized or improved in this group. CONCLUSIONS: Of patients with an ileal conduit 29% have renal function deterioration in the long term. No surgical cause for glomerular filtration rate deterioration was found in 18%. Important predisposing factors in nonobstructed cases were hypertension, recurrent urinary sepsis and a glomerular filtration rate of less than 50 ml per minute per 1.73 m. Hypertension was an independent predictor of a decreased glomerular filtration rate in the group with worsening glomerular filtration rates. In 11% of patients deterioration was due to upper tract obstruction. This was identifiable using renography and the glomerular filtration rate. A type IIIb curve was an early indicator of obstruction.


Files in this item

This item appears in the following Collection(s)

Show simple item record