Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom
Name:
Alzahrani_2024_Phys._Med._Biol ...
Size:
3.408Mb
Format:
PDF
Description:
Found with Open Access Button
Authors
Alzahrani, M.O'Hara, C.
Bird, D.
Baldwin, J. P. C.
Naisbit, M.
Teh, I.
Broadbent, D. A.
Al-Qaisieh, B.
Johnstone, Emily
Speight, R.
Affiliation
Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, United Kingdom.Issue Date
2024
Metadata
Show full item recordAbstract
Objective.This study aimed to optimise Cone Beam Computed Tomography (CBCT) protocols for head and neck (H&N) radiotherapy treatments using a 3D printed anthropomorphic phantom. It focused on precise patient positioning in conventional treatment and adaptive radiotherapy (ART).Approach.Ten CBCT protocols were evaluated with the 3D-printed H&N anthropomorphic phantom, including one baseline protocol currently used at our centre and nine new protocols. Adjustments were made to milliamperage and exposure time to explore their impact on radiation dose and image quality. Additionally, the effect on image quality of varying the scatter correction parameter for each of the protocols was assessed. Each protocol was compared against a reference CT scan. Usability was assessed by three Clinical Scientists using a Likert scale, and statistical validation was performed on the findings.Main results. The work revealed variability in the effectiveness of protocols. Protocols optimised for lower radiation exposure maintained sufficient image quality for patient setup in a conventional radiotherapy pathway, suggesting the potential for reducing patient radiation dose by over 50% without compromising efficacy. Optimising ART protocols involves balancing accuracy across brain, bone, and soft tissue, as no single protocol or scatter correction parameter achieves optimal results for all simultaneously.Significance.This study underscores the importance of optimising CBCT protocols in H&N radiotherapy. Our findings highlight the potential to maintain the usability of CBCT for bony registration in patient setup while significantly reducing the radiation dose, emphasizing the significance of optimising imaging protocols for the task in hand (registering to soft tissue or bone) and aligning with the as low as reasonably achievable principle. More studies are needed to assess these protocols for ART, including CBCT dose measurements and CT comparisons. Furthermore, the novel 3D printed anthropomorphic phantom demonstrated to be a useful tool when optimising CBCT protocols.Citation
Alzahrani M, O'Hara C, Bird D, Baldwin JPC, Naisbit M, Teh I, et al. Optimisation of cone beam CT radiotherapy imaging protocols using a novel 3D printed head and neck anthropomorphic phantom. Physics in medicine and biology. 2024 Oct 28;69(21). PubMed PMID: 39423848. Epub 2024/10/19. eng.Journal
Physics in Medicine and BiologyDOI
10.1088/1361-6560/ad88d2PubMed ID
39423848Additional Links
https://dx.doi.org/10.1088/1361-6560/ad88d2Type
ArticleLanguage
enae974a485f413a2113503eed53cd6c53
10.1088/1361-6560/ad88d2
Scopus Count
Collections
Related articles
- Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid.
- Authors: Stankovic U, van Herk M, Ploeger LS, Sonke JJ
- Issue date: 2014 Jun
- Technical assessment of a cone-beam CT scanner for otolaryngology imaging: image quality, dose, and technique protocols.
- Authors: Xu J, Reh DD, Carey JP, Mahesh M, Siewerdsen JH
- Issue date: 2012 Aug
- Evaluation of various approaches for assessing dose indicators and patient organ doses resulting from radiotherapy cone-beam CT.
- Authors: Rampado O, Giglioli FR, Rossetti V, Fiandra C, Ragona R, Ropolo R
- Issue date: 2016 May
- The impact of CBCT reconstruction and calibration for radiotherapy planning in the head and neck region - a phantom study.
- Authors: Elstrøm UV, Olsen SR, Muren LP, Petersen JB, Grau C
- Issue date: 2014 Aug
- Impact of different CBCT imaging monitor units, reconstruction slice thicknesses, and planning CT slice thicknesses on the positioning accuracy of a MV-CBCT system in head-and-neck patients.
- Authors: Jia MX, Zhang X, Li N, Han CB
- Issue date: 2012 Sep 6