• Login
    View Item 
    •   Home
    • The Christie Research Publications Repository
    • All Christie Publications
    • View Item
    •   Home
    • The Christie Research Publications Repository
    • All Christie Publications
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of ChristieCommunitiesTitleAuthorsIssue DateSubmit DateSubjectsThis CollectionTitleAuthorsIssue DateSubmit DateSubjectsProfilesView

    My Account

    LoginRegister

    Local Links

    The Christie WebsiteChristie Library and Knowledge Service

    Statistics

    Display statistics

    Investigating the impact of the interstitial fluid flow and hypoxia interface on cancer transcriptomes using a spheroid-on-chip perfusion system

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    d4lc00512k.pdf
    Size:
    3.588Mb
    Format:
    PDF
    Description:
    Found with Open Access Button
    Download
    Authors
    Pyne, E.
    Reardon, Mark
    Christensen, M.
    Rodriguez Mateos, P.
    Taylor, Scott
    Iles, A.
    Choudhury, Ananya
    Pamme, N.
    Pires, Isabel M
    Affiliation
    Translational Radiobiology, Division of Cancer Sciences, University of Manchester, Manchester, UK. Tumour Hypoxia Biology, Division of Cancer Sciences, University of Manchester, Manchester, UK. Isabel.pires-2@manchester.ac.uk. Christie Hospital NHS Foundation Trust, Manchester, UK.
    Issue Date
    2024
    
    Metadata
    Show full item record
    Abstract
    Solid tumours are complex and heterogeneous systems, which exist in a dynamic biophysical microenvironment. Conventional cancer research methods have long relied on two-dimensional (2D) static cultures which neglect the dynamic, three-dimensional (3D) nature of the biophysical tumour microenvironment (TME), especially the role and impact of interstitial fluid flow (IFF). To address this, we undertook a transcriptome-wide analysis of the impact of IFF-like perfusion flow using a spheroid-on-chip microfluidic platform, which allows 3D cancer spheroids to be integrated into extracellular matrices (ECM)-like hydrogels and exposed to continuous perfusion, to mimic IFF in the TME. Importantly, we have performed these studies both in experimental (normoxia) and pathophysiological (hypoxia) oxygen conditions. Our data indicated that gene expression was altered by flow when compared to static conditions, and for the first time showed that these gene expression patterns differed in different oxygen tensions, reflecting a differential role of spheroid perfusion in IFF-like flow in tumour-relevant hypoxic conditions in the biophysical TME. We were also able to identify factors primarily linked with IFF-like conditions which are linked with prognostic value in cancer patients and therefore could correspond to a potential novel biomarker of IFF in cancer. This study therefore highlights the need to consider relevant oxygen conditions when studying the impact of flow in cancer biology, as well as demonstrating the potential of microfluidic models of flow to identify IFF-relevant tumour biomarkers.
    Citation
    Pyne E, Reardon M, Christensen M, Rodriguez Mateos P, Taylor S, Iles A, et al. Investigating the impact of the interstitial fluid flow and hypoxia interface on cancer transcriptomes using a spheroid-on-chip perfusion system. Lab on a chip. 2024 Sep 24;24(19):4609-22. PubMed PMID: 39258507. Pubmed Central PMCID: PMC11388701. Epub 2024/09/11. eng.
    Journal
    Lab on a Chip
    URI
    http://hdl.handle.net/10541/627228
    DOI
    10.1039/d4lc00512k
    PubMed ID
    39258507
    Additional Links
    https://dx.doi.org/10.1039/d4lc00512k
    Type
    Article
    Language
    en
    ae974a485f413a2113503eed53cd6c53
    10.1039/d4lc00512k
    Scopus Count
    Collections
    All Christie Publications

    entitlement

    Related articles

    • In vitro lung cancer multicellular tumor spheroid formation using a microfluidic device.
    • Authors: Lee SW, Hong S, Jung B, Jeong SY, Byeon JH, Jeong GS, Choi J, Hwang C
    • Issue date: 2019 Nov
    • Spheroid-on-chip microfluidic technology for the evaluation of the impact of continuous flow on metastatic potential in cancer models in vitro.
    • Authors: Collins T, Pyne E, Christensen M, Iles A, Pamme N, Pires IM
    • Issue date: 2021 Jul
    • Detachably assembled microfluidic device for perfusion culture and post-culture analysis of a spheroid array.
    • Authors: Sakai Y, Hattori K, Yanagawa F, Sugiura S, Kanamori T, Nakazawa K
    • Issue date: 2014 Jul
    • High-throughput microfluidics for evaluating microbubble enhanced delivery of cancer therapeutics in spheroid cultures.
    • Authors: Bourn MD, Batchelor DVB, Ingram N, McLaughlan JR, Coletta PL, Evans SD, Peyman SA
    • Issue date: 2020 Oct 10
    • Rapid spheroid clearing on a microfluidic chip.
    • Authors: Silva Santisteban T, Rabajania O, Kalinina I, Robinson S, Meier M
    • Issue date: 2017 Dec 19
    DSpace software (copyright © 2002 - 2025)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.