Feasibility of dynamic T(2) *-based oxygen-enhanced lung MRI at 3T
Name:
Magnetic Resonance in Med - 2023 ...
Size:
5.402Mb
Format:
PDF
Description:
Found with Open Access Button
Authors
Kim, M.Naish, J. H.
Needleman, S. H.
Tibiletti, M.
Taylor, Y.
O'Connor, James P B
Parker, G. J. M.
Affiliation
Division of Cancer Sciences, University of Manchester, Manchester, UK.Issue Date
2024
Metadata
Show full item recordAbstract
PURPOSE: To demonstrate proof-of-concept of a T(2) *-sensitized oxygen-enhanced MRI (OE-MRI) method at 3T by assessing signal characteristics, repeatability, and reproducibility of dynamic lung OE-MRI metrics in healthy volunteers. METHODS: We performed sequence-specific simulations for protocol optimisation and acquired free-breathing OE-MRI data from 16 healthy subjects using a dual-echo RF-spoiled gradient echo approach at 3T across two institutions. Non-linear registration and tissue density correction were applied. Derived metrics included percent signal enhancement (PSE), ∆R(2) * and wash-in time normalized for breathing rate (τ-nBR). Inter-scanner reproducibility and intra-scanner repeatability were evaluated using intra-class correlation coefficient (ICC), repeatability coefficient, reproducibility coefficient, and Bland-Altman analysis. RESULTS: Simulations and experimental data show negative contrast upon oxygen inhalation, due to substantial dominance of ∆R(2) * at TE > 0.2 ms. Density correction improved signal fluctuations. Density-corrected mean PSE values, aligned with simulations, display TE-dependence, and an anterior-to-posterior PSE reduction trend at TE(1) . ∆R(2) * maps exhibit spatial heterogeneity in oxygen delivery, featuring anterior-to-posterior R(2) * increase. Mean T(2) * values across 32 scans were 0.68 and 0.62 ms for pre- and post-O(2) inhalation, respectively. Excellent or good agreement emerged from all intra-, inter-scanner and inter-rater variability tests for PSE and ∆R(2) *. However, ICC values for τ-nBR demonstrated limited agreement between repeated measures. CONCLUSION: Our results demonstrate the feasibility of a T(2) *-weighted method utilizing a dual-echo RF-spoiled gradient echo approach, simultaneously capturing PSE, ∆R(2) * changes, and oxygen wash-in during free-breathing. The excellent or good repeatability and reproducibility on intra- and inter-scanner PSE and ∆R(2) * suggest potential utility in multi-center clinical applications.Citation
Kim M, Naish JH, Needleman SH, Tibiletti M, Taylor Y, O'Connor JPB, et al. Feasibility of dynamic T(2) *-based oxygen-enhanced lung MRI at 3T. Magnetic resonance in medicine. 2024 Mar;91(3):972-86. PubMed PMID: 38013206. Epub 2023/11/28. eng.Journal
Magnetic Resonance in MedicineDOI
10.1002/mrm.29914PubMed ID
38013206Additional Links
https://dx.doi.org/10.1002/mrm.29914Type
ArticleLanguage
enae974a485f413a2113503eed53cd6c53
10.1002/mrm.29914