Show simple item record

dc.contributor.authorMul, J.
dc.contributor.authorMelchior, P.
dc.contributor.authorSeravalli, E.
dc.contributor.authorSaunders, Daniel
dc.contributor.authorBolle, S.
dc.contributor.authorCameron, A. L.
dc.contributor.authorGurtner, K.
dc.contributor.authorHarrabi, S.
dc.contributor.authorLassen-Ramshad, Y.
dc.contributor.authorLavan, N.
dc.contributor.authorMagelssen, H.
dc.contributor.authorMandeville, H.
dc.contributor.authorBoterberg, T.
dc.contributor.authorKroon, P. S.
dc.contributor.authorKotte, A.
dc.contributor.authorHoeben, B. A. W.
dc.contributor.authorvan Rossum, P. S. N.
dc.contributor.authorvan Grotel, M.
dc.contributor.authorGraf, N.
dc.contributor.authorvan den Heuvel-Eibrink, M. M.
dc.contributor.authorRübe, C.
dc.contributor.authorJanssens, G. O.
dc.date.accessioned2021-04-20T08:08:22Z
dc.date.available2021-04-20T08:08:22Z
dc.date.issued2021en
dc.identifier.citationMul J, Melchior P, Seravalli E, Saunders D, Bolle S, Cameron AL, et al. Inter-clinician delineation variation for a new highly-conformal flank target volume in children with renal tumors: A SIOP-Renal Tumor Study Group international multicenter exercise. Clin Transl Radiat Oncol. 2021;28:39-47.en
dc.identifier.pmid33796796en
dc.identifier.doi10.1016/j.ctro.2021.03.001en
dc.identifier.urihttp://hdl.handle.net/10541/623945
dc.description.abstractBackground and purpose: Recently, the SIOP-RTSG developed a highly-conformal flank target volume definition for children with renal tumors. The aims of this study were to evaluate the inter-clinician delineation variation of this new target volume definition in an international multicenter setting and to explore the necessity of quality assurance. Materials and methods: Six pediatric renal cancer cases were transferred to ten radiation oncologists from seven European countries ('participants'). These participants delineated the pre- and postoperative Gross Tumor Volume (GTVpre/post), and Clinical Target Volume (CTV) during two test phases (case 1-2 and 3-4), followed by guideline refinement and a quality assurance phase (case 5-6). Reference target volumes (TVref) were established by three experienced radiation oncologists. The Dice Similarity Coefficient between the reference and participants (DSCref/part) was calculated per case. Delineations of case 5-6 were graded by four independent reviewers as 'per protocol' (0-4 mm), 'minor deviation' (5-9 mm) or 'major deviation' (≥10 mm) from the delineation guideline using 18 standardized criteria. Also, a major deviation resulting in underestimation of the CTVref was regarded as an unacceptable variation. Results: A total of 57/60 delineation sets were completed. The median DSCref/part for the CTV was 0.55 without improvement after sequential cases (case 3-4 vs. case 5-6: p = 0.15). For case 5-6, a major deviation was found for 5/18, 12/17, 18/18 and 4/9 collected delineations of the GTVpre, GTVpost, CTV-T and CTV-N, respectively. An unacceptable variation from the CTVref was found for 7/9 participants for case 5 and 6/9 participants for case 6. Conclusion: This international multicenter delineation exercise demonstrates that the new consensus for highly-conformal postoperative flank target volume delineation leads to geometrical variation among participants. Moreover, standardized review showed an unacceptable delineation variation in the majority of the participants. These findings strongly suggest the need for additional training and centralized pre-treatment review when this target volume delineation approach is implemented on a larger scale.en
dc.language.isoenen
dc.relation.urlhttps://dx.doi.org/10.1016/j.ctro.2021.03.001en
dc.titleInter-clinician delineation variation for a new highly-conformal flank target volume in children with renal tumors: A SIOP-Renal Tumor Study Group international multicenter exerciseen
dc.typeArticleen
dc.contributor.departmentPrincess Máxima Center for Pediatric Oncology, Utrecht, the Netherlandsen
dc.identifier.journalClinical and Translational Radiation Oncologyen
dc.description.noteen]
refterms.dateFOA2021-04-26T10:52:19Z


Files in this item

Thumbnail
Name:
Inter-clinician delineation ...
Size:
1.788Mb
Format:
PDF
Description:
From UNPAYWALL

This item appears in the following Collection(s)

Show simple item record