Novel methodology to assess the effect of contouring variation on treatment outcome
Authors
Jenkins, A.Soares Mullen, T.
Johnson-Hart, Corinne
Green, Andrew
McWilliam, Alan
Aznar, Marianne Camille
van Herk, Marcel
Vasquez Osorio, Eliana
Affiliation
University of Manchester, School of Physics & Astronomy - Faculty of Science and Engineering, Manchester, M13 9PIssue Date
2021
Metadata
Show full item recordAbstract
Purpose: Contouring variation is one of the largest systematic uncertainties in radiotherapy, yet its effect on clinical outcome has never been analysed quantitatively. We propose a novel, robust methodology to locally quantify target contour variation in a large patient cohort and find where this variation correlates with treatment outcome. We demonstrate its use on biochemical recurrence for prostate cancer patients. Method: We propose to compare each patient's target contours to a consistent and unbiased reference. This reference was created by auto-contouring each patient's target using an externally trained deep learning algorithm. Local contour deviation measured from the reference to the manual contour were projected to a common frame of reference, creating contour deviation maps for each patient. By stacking the contour deviation maps, time to event was modelled pixel-wise using a multivariate Cox proportional hazards model (CPHM). Hazard ratio (HR) maps for each covariate were created, and regions of significance found using cluster-based permutation testing on the z-statistics. This methodology was applied to Clinical Target Volume (CTV) contours, containing only the prostate gland, from 232 intermediate- and high-risk prostate cancer patients. The reference contours were created using ADMIRE® v3.4 (Elekta AB, Sweden). Local contour deviations were computed in a spherical coordinate frame, where differences between reference and clinical contours were projected in a 2D map corresponding to sampling across the coronal and transverse angles every 3°. Time to biochemical recurrence was modelled using the pixel-wise CPHM analysis accounting for contour deviation, patient age, Gleason score and treated CTV volume. Results: We successfully applied the proposed methodology to a large patient cohort containing data from 232 patients. In this patient cohort, our analysis highlighted regions where the contour variation was related to biochemical recurrence, producing expected and unexpected results: 1) the interface between prostate-bladder and prostate-seminal vesicle interfaces where increase of the manual contour relative to the reference was related to a reduction of risk of biochemical recurrence by 4-8% per mm and 2) the prostate's right, anterior and posterior regions where an increase of the manual contour relative to the reference contours was related to an increase of risk of biochemical recurrence by 8-24% per mm. Conclusion: We proposed and successfully applied a novel methodology to explore the correlation between contour variation and treatment outcome. We analysed the effect of contour deviation of the prostate CTV on biochemical recurrence for a cohort of more than 200 prostate cancer patients while taking basic clinical variables into account. Applying this methodology to a larger dataset including additional clinically important covariates and externally validating it can more robustly identify regions where contour variation directly relates to treatment outcome. For example, in the prostate case we use to demonstrate our novel methodology, external validation will help confirm or reject the counter-intuitive results (larger contours resulting in higher risk). Ultimately, the results of this methodology could inform contouring protocols based on actual patient outcomes.Citation
Jenkins A, Soares Mullen T, Johnson-Hart C, Green A, McWilliam A, Aznar M, et al. Novel Methodology to assess the Effect of Contouring Variation on Treatment Outcome. Med Phys. 2021.Journal
Medical PhysicsDOI
10.1002/mp.14865PubMed ID
33772803Additional Links
https://dx.doi.org/10.1002/mp.14865Type
ArticleLanguage
enae974a485f413a2113503eed53cd6c53
10.1002/mp.14865
Scopus Count
Collections
Related articles
- Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning.
- Authors: Fiorino C, Reni M, Bolognesi A, Cattaneo GM, Calandrino R
- Issue date: 1998 Jun
- Clinical Evaluation of Deep Learning and Atlas-Based Auto-Contouring of Bladder and Rectum for Prostate Radiation Therapy.
- Authors: Zabel WJ, Conway JL, Gladwish A, Skliarenko J, Didiodato G, Goorts-Matthews L, Michalak A, Reistetter S, King J, Nakonechny K, Malkoske K, Tran MN, McVicar N
- Issue date: 2021 Jan-Feb
- Evaluation of a commercial DIR platform for contour propagation in prostate cancer patients treated with IMRT/VMAT.
- Authors: Hammers JE, Pirozzi S, Lindsay D, Kaidar-Person O, Tan X, Chen RC, Das SK, Mavroidis P
- Issue date: 2020 Feb
- Contouring variability of human- and deformable-generated contours in radiotherapy for prostate cancer.
- Authors: Gardner SJ, Wen N, Kim J, Liu C, Pradhan D, Aref I, Cattaneo R, Vance S, Movsas B, Chetty IJ, Elshaikh MA
- Issue date: 2015 Jun 7
- Prospects for daily online adaptive radiotherapy via ethos for prostate cancer patients without nodal involvement using unedited CBCT auto-segmentation.
- Authors: Moazzezi M, Rose B, Kisling K, Moore KL, Ray X
- Issue date: 2021 Oct