Show simple item record

dc.contributor.authorPola, A.
dc.contributor.authorBortot, D.
dc.contributor.authorMazzucconi, D.
dc.contributor.authorFazzi, A.
dc.contributor.authorGaler, S.
dc.contributor.authorKirkby, Karen J
dc.contributor.authorMerchant, Michael J
dc.contributor.authorPalmans, H.
dc.contributor.authorAgosteo, S.
dc.date.accessioned2020-06-16T11:03:18Z
dc.date.available2020-06-16T11:03:18Z
dc.date.issued2020en
dc.identifier.citationA. Pola, D. Bortot, D. Mazzucconi et al. Characterization of a pixelated silicon microdosimeter in micro-beams of light ions. Radiation Measurements. 2020;133en
dc.identifier.doi10.1016/j.radmeas.2020.106296en
dc.identifier.urihttp://hdl.handle.net/10541/623048
dc.description.abstractThe monolithic silicon telescope technology allows to produce solid state microdosimeters. A detector constituted by a matrix of pixels (2 'm in thickness) coupled with a deeper stage (about 500 'm in thickness) was designed, developed and characterized by comparing its response against Tissue Equivalent Proportional Counters (TEPCs) in different irradiation fields, showing promising results. Each pixel of the 'E stage is a thin diode of 9 'm in diameter delimited by a guard ring of 14 'm in diameter. The aim of this work is the study of the charge collection efficiency of the single pixel of the silicon microdosimeter by irradiating a prototype at the micro-beam facility of the Ion Beam Center - IBC of the University of Surrey. Different light ions were exploited (protons, lithium ions and carbon ions) and scanned on different positions on and around a single pixel of the detector. The results show that the charge generated by events on the sensitive region of the 'E stage is completely collected, while a charge collection efficiency lower than one characterizes the region between the central pixel and its guard ring. The guard ring delimits properly the sensitive region: no signals arise from events outside the 14 'm in diameter ring. Nevertheless, the microdosimetric distributions of the different charged particles highlight a minor distortion in terms of the absorbed dose. This latter result justifies the good agreement with TEPCs in terms of microdosimetric distributions in different hadrons beams described in previous works.en
dc.language.isoenen
dc.relation.urlhttps://dx.doi.org/10.1016/j.radmeas.2020.106296en
dc.titleCharacterization of a pixelated silicon microdosimeter in micro-beams of light ionsen
dc.typeArticleen
dc.contributor.departmentPolitecnico di Milano, Milano, Italyen
dc.identifier.journalRadiation Measurementsen
dc.description.noteen]