dc.description.abstractOBJECTIVE: To investigate the effects of Image Biomarker Standardisation Initiative (IBSI) compliance, harmonisation of calculation settings and platform version on the statistical reliability of radiomic features and their corresponding ability to predict clinical outcome. METHODS: The statistical reliability of radiomic features was assessed retrospectively in three clinical datasets (patient numbers: 108 head and neck cancer, 37 small-cell lung cancer, 47 non-small-cell lung cancer). Features were calculated using four platforms (PyRadiomics, LIFEx, CERR and IBEX). PyRadiomics, LIFEx and CERR are IBSI-compliant, whereas IBEX is not. The effects of IBSI compliance, user-defined calculation settings and platform version were assessed by calculating intraclass correlation coefficients and confidence intervals. The influence of platform choice on the relationship between radiomic biomarkers and survival was evaluated using univariable cox regression in the largest dataset. RESULTS: The reliability of radiomic features calculated by the different software platforms was only excellent (ICC 0.9) for 4/17 radiomic features when comparing all four platforms. Reliability improved to ICC " 0.9 for 15/17 radiomic features when analysis was restricted to the three IBSI-compliant platforms. Failure to harmonise calculation settings resulted in poor reliabilityen
dc.language.isoenen
dc.relation.urlhttps://dx.doi.org/10.1007/s00330-020-06957-9en
dc.titleReliability and prognostic value of radiomic features are highly dependent on choice of feature extraction platformen
dc.typeArticleen
dc.contributor.departmentDivision of Cancer Sciences, University of Manchester, Manchester, UK.en
dc.identifier.journalEuropean Radiologyen
dc.description.noteen]