• An analysis of breast motion using high-frequency, dense surface points captured by an optical sensor during radiotherapy treatment delivery.

      Price, Gareth J; Sharrock, Phillip J; Marchant, Thomas E; Parkhurst, J M; Burton, D; Jain, Pooja; Price, Patricia M; Moore, Christopher J; North Western Medical Physics, The Christie NHS Foundation Trust, Manchester, UK. Gareth.Price@physics.cr.man.ac.uk (2009-11-07)
      Patient motion is an important factor affecting the quality of external beam radiotherapy in breast patients. We analyse the motion of a dense set of surface points on breast patients throughout their treatment schedule to assess the magnitude and stability of motion, in particular, with respect to breast volume. We use an optical sensor to measure the surface motion of 13 breast cancer patients. Patients were divided into two cohorts dependent upon breast volume. Measurements were made during radiotherapy treatment beam delivery for an average of 12 fractions per patient (total 158 datasets). The motion of each surface point is parameterized in terms of its period, amplitude and relative phase. Inter-comparison of the motion parameters across treatment schedules and between patients is made through the creation of corresponding regions on the breast surfaces. The motion period is spatially uniform and is similar in both patient groups (mean 4 s), with the small volume cohort exhibiting greater inter-fraction period variability. The mean motion amplitude is also similar in both groups with a range between 2 mm and 4 mm and an inter-fraction variability generally less than 1 mm. There is a phase lag of up to 0.4 s across the breast, led by the sternum. Breast patient motion is reasonably stable between and during treatment fractions, with the large volume cohort exhibiting greater repeatability than the small volume one.
    • Assessment of bladder motion for clinical radiotherapy practice using cine-magnetic resonance imaging.

      McBain, Catherine A; Khoo, Vincent S; Buckley, David L; Sykes, Jonathan S; Green, Melanie M; Cowan, Richard A; Hutchinson, Charles E; Moore, Christopher J; Price, Patricia M; Academic Department of Radiation Oncology, The University of Manchester, Christie Hospital NHS Foundation Trust, Wilmslow Road, Manchester, United Kingdom. (2009-11-01)
      PURPOSE: Organ motion is recognized as the principal source of inaccuracy in bladder radiotherapy (RT), but there is currently little information on intrafraction bladder motion. METHODS AND MATERIALS: We used cine-magnetic resonance imaging (cine-MRI) to study bladder motion relevant to intrafraction RT delivery. On two occasions, a 28 minute cine-MRI sequence was acquired from 10 bladder cancer patients and 5 control participants immediately after bladder emptying, after abstinence from drinking for the preceding hour. From the resulting cine sequences, bladder motion was subjectively assessed. To quantify bladder motion, the bladder was contoured in imaging volume sets at 0, 14, and 28 min to measure changes to bladder volumes, wall displacements, and center of gravity (COG) over time. RESULTS: The dominant source of bladder motion during imaging was bladder filling (up to 101% volume increase); rectal and small bowel movements were transient, with minimal impact. Bladder volume changes were similar for all participants. However for bladder cancer patients, wall displacements were larger (up to 58 mm), less symmetrical, and more variable compared with nondiseased control bladders. CONCLUSIONS: Significant and individualized intrafraction bladder wall displacements may occur during bladder RT delivery. This important source of inaccuracy should be incorporated into treatment planning and verification.
    • Blood flow and Vd (water): both biomarkers required for interpreting the effects of vascular targeting agents on tumor and normal tissue.

      Kötz, Barbara; West, Catharine M L; Saleem, Azeem; Jones, Terry; Price, Patricia M; Academic Department of Radiation Oncology, The University of Manchester, Manchester, UK. (2009-02)
      Positron emission tomography studies with oxygen-15-labeled water provide in vivo quantitative tissue perfusion variables-blood flow and fractional volume of distribution of water [V(d) (water)]. To investigate the relationship between perfusion variables and the effect of vascular-targeting agents on vasculature, we measured tissue perfusion in tumors, spleen, kidney, and liver before and after treatment with combretastatin-A4-phosphate, a combination of nicotinamide and carbogen (N/C), and interferon (IFN). We observed that mean tumor blood flow and V(d) (water) was lower than in kidney, liver, and spleen at baseline. Blood flow and V(d) (water) were related in tumor (r = 0.62; P = 0.004) at baseline, but not in other normal tissues evaluated, where minimal variations in V(d) (water) were observed over a wide range of blood flow. Despite the relationship between blood flow and V(d) (water) in tumors before intervention, vascular-targeting agent-induced changes in these perfusion variables were not correlated. In contrast, changes in blood flow and V(d) (water) correlated in kidney and spleen after N/C and in kidney after combretastatin-A4-phosphate. The close relation between blood flow and V(d) (water) in tumors but not normal tissue may reflect barriers to fluid exchange in tumors because of necrosis and/or increased interstitial fluid pressure and underlies the importance and interdependence of these positron emission tomography perfusion variables under these conditions. As blood flow and V(d) (water) signify different aspects of tissue perfusion, the differential effects of interventions on both variables, flow and V(d) (water), should therefore be reported in future studies.
    • Chemoradiotherapy for locally advanced pancreatic cancer: a radiotherapy dose escalation and organ motion study.

      Henry, Ann M; Ryder, W David J; Moore, Christopher J; Sherlock, David J; Geh, J I; Dunn, P; Price, Patricia M; Academic Department of Radiation Oncology, The University of Manchester, Department of Medical Statistics, Christie Hospital NHS Trust, Manchester, UK. (2008-09)
      AIMS: To determine the efficacy of radiation dose escalation and to examine organ motion during conformal radiotherapy for locally advanced pancreatic cancer. MATERIALS AND METHODS: Thirty-nine patients who were consecutively treated with chemoradiotherapy were studied. Fifteen patients, treated from 1993 to 1997, received 50 Gy in 20 fractions (group I). Twenty-four patients, treated from 1997 to 2003, received an escalated dose of 55 Gy in 25 fractions (group II). Intra-fraction pancreatic tumour motion was assessed in three patients using megavoltage movies during radiation delivery to track implanted radio-opaque markers. RESULTS: Improved survival rates were seen in latterly treated group II patients (P=0.083), who received escalated radiotherapy to smaller treatment volumes due to advances in verification. Worse toxicity effects (World Health Organization grade 3-4) were reported by some patients (<10%), but treatment compliance was similar in both groups, indicating equivalent tolerance. Substantial intra-fraction tumour displacement due to respiratory motion was observed: this was greatest in the superior/inferior (mean=6.6 mm) and anterior/posterior (mean=4.75 mm) directions. Lateral displacements were small (<2 mm). CONCLUSIONS: Dose escalation is feasible in pancreatic cancer, particularly when combined with a reduction in irradiated volume, and enhanced efficacy is indicated. Large, globally applied margins to compensate for pancreatic tumour motion during radiotherapy may be inappropriate. Strategies to reduce respiratory motion, and/or the application of image-guided techniques that incorporate individual patients' respiratory motion into radiotherapy planning and delivery, will probably improve pancreatic radiotherapy.
    • Dynamic contrast-enhanced MRI for prostate cancer localization.

      Jackson, Andrew; Reinsberg, S A; Sohaib, S A; Charles-Edwards, E M; Jhavar, S; Christmas, T J; Thompson, A C; Bailey, M J; Corbishley, C M; Fisher, C; et al. (2009-02)
      Radiotherapy dose escalation improves tumour control in prostate cancer but with increased toxicity. Boosting focal tumour only may allow dose escalation with acceptable toxicity. Intensity-modulated radiotherapy can deliver this, but visualization of the tumour remains limiting. CT or conventional MRI techniques are poor at localizing tumour, but dynamic contrast-enhanced MRI (DCE-MRI) may be superior. 18 patients with prostate cancer had T(2) weighted (T2W) and DCE-MRI prior to prostatectomy. The prostate was sectioned meticulously so as to achieve accurate correlation between imaging and pathology. The accuracy of DCE-MRI for cancer detection was calculated by a pixel-by-pixel correlation of quantitative DCE-MRI parameter maps and pathology. In addition, a radiologist interpreted the DCE-MRI and T2W images. The location of tumour on imaging was compared with histology, and the accuracy of DCE-MRI and T2W images was then compared. Pixel-by-pixel comparison of quantitative parameter maps showed a significant difference between the benign peripheral zone and tumour for the parameters K(trans), v(e) and k(ep). Calculation of areas under the receiver operating characteristic curve showed that the pharmacokinetic parameters were only "fair" discriminators between cancer and benign gland. Interpretation of DCE-MRI and T2W images by a radiologist showed DCE-MRI to be more sensitive than T2W images for tumour localization (50% vs 21%; p = 0.006) and similarly specific (85% vs 81%; p = 0.593). The superior sensitivity of DCE-MRI compared with T2W images, together with its high specificity, is arguably sufficient for its use in guiding radiotherapy boosts in prostate cancer.
    • Early clinical evaluation of a novel three-dimensional structure delineation software tool (SCULPTER) for radiotherapy treatment planning.

      McBain, Catherine A; Moore, Christopher J; Green, Matthew M L; Price, Gareth J; Sykes, Jonathan R; Amer, Aminah; Khoo, Vincent S; Price, Patricia M; Academic Department of Radiation Oncology, The University of Manchester, Manchester, UK. (2008-08)
      Modern radiotherapy treatment planning (RTP) necessitates increased delineation of target volumes and organs at risk. Conventional manual delineation is a laborious, time-consuming and subjective process. It is prone to inconsistency and variability, but has the potential to be improved using automated segmentation algorithms. We carried out a pilot clinical evaluation of SCULPTER (Structure Creation Using Limited Point Topology Evidence in Radiotherapy) - a novel prototype software tool designed to improve structure delineation for RTP. Anonymized MR and CT image datasets from patients who underwent radiotherapy for bladder or prostate cancer were studied. An experienced radiation oncologist used manual and SCULPTER-assisted methods to create clinically acceptable organ delineations. SCULPTER was also tested by four other RTP professionals. Resulting contours were compared by qualitative inspection and quantitatively by using the volumes of the structures delineated and the time taken for completion. The SCULPTER tool was easy to apply to both MR and CT images and diverse anatomical sites. SCULPTER delineations closely reproduced manual contours with no significant volume differences detected, but SCULPTER delineations were significantly quicker (p<0.05) in most cases. In conclusion, clinical application of SCULPTER resulted in rapid and simple organ delineations with equivalent accuracy to manual methods, demonstrating proof-of-principle of the SCULPTER system and supporting its potential utility in RTP.
    • Hypoxia-associated markers in gastric carcinogenesis and HIF-2alpha in gastric and gastro-oesophageal cancer prognosis.

      Griffiths, Ewen A; Pritchard, S A; McGrath, S M; Valentine, Helen R; Price, Patricia M; Welch, I M; West, Catharine M L; Academic Department of Radiation Oncology, School of Cancer & Imaging Sciences, The University of Manchester, Christie Hospital, Wilmslow Road, Withington, Manchester M20 4BX, UK. (2008-03-11)
      The study investigated hypoxia-associated markers (HIF-2alpha, Epo, Epo-R, Glut-1 and VEGF) along with Ki-67 in a gastric carcinogenesis model, and the prognostic significance of hypoxia-inducible factor (HIF)-2alpha in surgically treated gastro-oesophageal cancer. Protein expression was examined using immunohistochemistry on formalin-fixed, paraffin-embedded biopsies of normal mucosa (n=20), Helicobacter pylori-associated gastritis (n=24), intestinal metaplasia (n=24), dysplasia (n=12) and intestinal (n=19) and diffuse (n=21) adenocarcinoma. Relationships between HIF-2alpha expression and prognosis were assessed in resection specimens from 177 patients with gastric and gastro-oesophageal junction adenocarcinoma. Expression of all markers increased with progression along the gastric carcinogenesis sequence (P=0.0001). Hypoxia-inducible factor-2alpha was expressed in 63% of 177 resection specimens and at a high level in 44%. The median overall survival in patients with HIF-2alpha-expressing tumours was 22 (95% CI 18-26) months, whereas those with HIF-2alpha-negative tumours had a median survival of 37 (95% CI 29-44) months (P=0.015). Hypoxia-inducible factor-2alpha had no independent prognostic significance in multivariate analysis. In view of the lack of independent prognostic significance, HIF-2alpha has no role as a routine prognostic indicator. However, the high expression of HIF-2alpha suggests that it may be of value as a potential therapeutic target.
    • Monitoring dosimetric impact of weight loss with kilovoltage (kV) cone beam CT (CBCT) during parotid-sparing IMRT and concurrent chemotherapy.

      Ho, Kean F; Marchant, Thomas E; Moore, Christopher J; Webster, Gareth J; Rowbottom, Carl G; Pennington, Hazel; Lee, Lip W; Yap, Beng K; Sykes, Andrew J; Slevin, Nicholas J; et al. (2012-03-01)
      Parotid-sparing head-and-neck intensity-modulated radiotherapy (IMRT) can reduce long-term xerostomia. However, patients frequently experience weight loss and tumor shrinkage during treatment. We evaluate the use of kilovoltage (kV) cone beam computed tomography (CBCT) for dose monitoring and examine if the dosimetric impact of such changes on the parotid and critical neural structures warrants replanning during treatment.
    • Preliminary study of oxygen-enhanced longitudinal relaxation in MRI: a potential novel biomarker of oxygenation changes in solid tumors.

      O'Connor, James P B; Naish, Josephine H; Parker, Geoff J M; Waterton, John C; Watson, Yvonne; Jayson, Gordon C; Buonaccorsi, Giovanni A; Cheung, Susan; Buckley, David L; McGrath, Deirdre M; et al. (2009-11-15)
      PURPOSE: There is considerable interest in developing non-invasive methods of mapping tumor hypoxia. Changes in tissue oxygen concentration produce proportional changes in the magnetic resonance imaging (MRI) longitudinal relaxation rate (R(1)). This technique has been used previously to evaluate oxygen delivery to healthy tissues and is distinct from blood oxygenation level-dependent (BOLD) imaging. Here we report application of this method to detect alteration in tumor oxygenation status. METHODS AND MATERIALS: Ten patients with advanced cancer of the abdomen and pelvis underwent serial measurement of tumor R(1) while breathing medical air (21% oxygen) followed by 100% oxygen (oxygen-enhanced MRI). Gadolinium-based dynamic contrast-enhanced MRI was then performed to compare the spatial distribution of perfusion with that of oxygen-induced DeltaR(1). RESULTS: DeltaR(1) showed significant increases of 0.021 to 0.058 s(-1) in eight patients with either locally recurrent tumor from cervical and hepatocellular carcinomas or metastases from ovarian and colorectal carcinomas. In general, there was congruency between perfusion and oxygen concentration. However, regional mismatch was observed in some tumor cores. Here, moderate gadolinium uptake (consistent with moderate perfusion) was associated with low area under the DeltaR(1) curve (consistent with minimal increase in oxygen concentration). CONCLUSIONS: These results provide evidence that oxygen-enhanced longitudinal relaxation can monitor changes in tumor oxygen concentration. The technique shows promise in identifying hypoxic regions within tumors and may enable spatial mapping of change in tumor oxygen concentration.
    • Rectal motion can reduce CTV coverage and increase rectal dose during prostate radiotherapy: A daily cone-beam CT study.

      Sripadam, Raj; Stratford, Julia; Henry, Ann M; Jackson, Andrew; Moore, Christopher J; Price, Patricia M; Clatterbridge Centre for Oncology, Bebington, Wirral, UK. (2009-03)
      BACKGROUND AND PURPOSE: Daily on-treatment verification cone-beam CT (CBCT) was used to study the effect of rectal motion on clinical target volume (CTV) coverage during prostate radiotherapy. MATERIAL AND METHODS: CBCT scans were acquired from 15 patients immediately after daily treatment. From these images, the rectum was contoured allowing the analysis of rectal volume cross-sectional area (CSA) and the determination of rectal dose. Rectal wall motion was quantified as a surrogate measure of prostate displacement and CTV coverage was subjectively assessed. RESULTS: Rectal volume decreased over the treatment course in 13 patients (P<0.001). Rectal wall regions corresponding to the prostate base displayed the greatest motion; larger displacements were seen in patients with larger rectal planning volumes. CTV coverage was inadequate, at the prostate base only, in 38% of the fractions delivered to 4/7 patients with a large rectum at planning (>100 cm(3)). In patients with small rectum at planning (<50 cm(3)) up to 25% more rectal volume than predicted was included in the high-dose region. CONCLUSIONS: Rectal motion during treatment in prostate cancer patients has implications for CTV coverage and rectal dose. Measures to ensure consistency in daily rectal volume or image-guided strategies should be considered.
    • Use of multiple biological markers in radiotherapy-treated head and neck cancer.

      Silva, Priyamal; Slevin, Nicholas J; Sloan, Philip; Valentine, Helen R; Ryder, W David J; Price, Patricia M; West, Catharine M L; Homer, Jarrod J; School of Cancer & Enabling Sciences, The University of Manchester, Manchester, UK. (2010-06)
      OBJECTIVE: Management of patients with head and neck squamous cell carcinoma is often based on clinical parameters, with little appreciation of the underlying tumour biology. Single biological marker studies fail to acknowledge the complexity of these tumours. Our aim was to define a profile of biological markers associated with outcome. DESIGN: This retrospective study involved consecutive patients with oropharyngeal squamous cell carcinoma treated with primary radiotherapy between 1996 and 2001. Pre-treatment biopsies were used to study the immunohistochemical expression of nine biological markers. Markers were chosen to reflect biologically relevant pathways. RESULTS: Following analysis of nine markers, a profile of two markers was derived (carbonic anhydrase 9 and major vault protein), the co-expression of which conferred a significantly poor probability of locoregional control. The prognostic effect of these biomarkers in combination was greater than their effect individually. CONCLUSION: Biomarker profiles can be established which highlight large differences in locoregional control. Identifying tumours that express both carbonic anhydrase 9 and major vault protein may facilitate patient selection for more aggressive treatment.