    Marvin: an anatomical phantom for dosimetric evaluation of complex radiotherapy of the head and neck.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Authors
    Aitkenhead, Adam H
    Rowbottom, Carl G
    Mackay, Ranald I
    Affiliation
    Christie Medical Physics and Engineering, The Christie NHS Foundation Trust, Manchester, UK. Manchester Academic Health Science Centre (MAHSC), Faculty of Medical and Human Sciences, University of Manchester, Manchester, UK.
    Issue Date
    2013-10-07
    
    Metadata
    Show full item record
    Abstract
    We report on the design of Marvin, a Model Anatomy for Radiotherapy Verification and audit In the head and Neck and present results demonstrating its use in the development of the Elekta volumetric modulated arc therapy (VMAT) technique at the Christie, and in the audit of TomoTherapy and Varian RapidArc at other institutions. The geometry of Marvin was generated from CT datasets of eight male and female patients lying in the treatment position, with removable inhomogeneities modelling the sinuses and mandible. A modular system allows the phantom to be used with a range of detectors, with the locations of the modules being based on an analysis of a range of typical treatment plans (27 in total) which were mapped onto the phantom geometry. Results demonstrate the use of Gafchromic EBT2/EBT3 film for measurement of relative dose in a plane through the target and organs-at-risk, and the use of a small-volume ionization chamber for measurement of absolute dose in the target and spinal cord. Measurements made during the development of the head and neck VMAT protocol at the Christie quantified the improvement in plan delivery resulting from the installation of the Elekta Integrity upgrade (which permits an effectively continuously variable dose rate), with plans delivered before and after the upgrade having 88.5 ± 9.4% and 98.0 ± 2.2% respectively of points passing a gamma analysis (at 4%, 4 mm, global). Audits of TomoTherapy and Varian RapidArc neck techniques at other institutions showed a similar quality of plan delivery as for post-Integrity Elekta VMAT: film measurements for both techniques had >99% of points passing a gamma analysis at the clinical criteria of 4%, 4 mm, global, and >95% of points passing at tighter criteria of 3%, 3 mm, global; and absolute dose measurements in the PTV and spinal cord were within 1.5% and 3.5% of the planned doses respectively for both techniques. The results demonstrate that Marvin is an efficient and effective means of assessing the quality of delivery of complex radiotherapy in the head and neck, and is a useful tool to assist development and audit of these techniques.
    Citation
    Marvin: an anatomical phantom for dosimetric evaluation of complex radiotherapy of the head and neck. 2013, 58 (19):6915-29 Phys Med Biol
    Journal
    Physics in Medicine and Biology
    URI
    http://hdl.handle.net/10541/302262
    DOI
    10.1088/0031-9155/58/19/6915
    PubMed ID
    24029583
    Type
    Article
    Language
    en
    ISSN
    1361-6560
    ae974a485f413a2113503eed53cd6c53
    10.1088/0031-9155/58/19/6915
    Scopus Count
    Collections
    All Christie Publications

    entitlement

    Related articles

    • A comparison of several modulated radiotherapy techniques for head and neck cancer and dosimetric validation of VMAT.
    • Authors: Stieler F, Wolff D, Schmid H, Welzel G, Wenz F, Lohr F
    • Issue date: 2011 Dec
    • A Monte Carlo tool for evaluating VMAT and DIMRT treatment deliveries including planar detectors.
    • Authors: Asuni G, van Beek TA, Venkataraman S, Popescu IA, McCurdy BM
    • Issue date: 2013 Jun 7
    • Dosimetric verification of RapidArc treatment delivery.
    • Authors: Korreman S, Medin J, Kjaer-Kristoffersen F
    • Issue date: 2009
    • Evaluation criteria for film based intensity modulated radiation therapy quality assurance.
    • Authors: Anjum MN, Parker W, Ruo R, Afzal M
    • Issue date: 2010 Jan
    • Evaluation of the Delta4 phantom for IMRT and VMAT verification.
    • Authors: Bedford JL, Lee YK, Wai P, South CP, Warrington AP
    • Issue date: 2009 May 7
    DSpace software (copyright © 2002 - 2025)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.