Loading...
Thumbnail Image
Publication

The use of a combined radial forearm flap and radial fascial flap for layered dural lining and an orbital defect reconstruction.

Bondin, D
Ross, Gary L
Citations
Altmetric:
Abstract
Variable reconstruction methods for craniofacial tumour resections have been devised with the primary purpose to improve quality of life and disease control. The reconstructive aims are to provide a watertight seal, cranial base support while allowing a cosmetically pleasing result. For defects involving the orbit, maintenance of the depth of the orbital socket remains important for prosthetic fitting and a bulky flap is not advisable for this purpose. This case demonstrates the use of a combination pericranial flap, radial forearm fascial flap and cutaneous radial forearm flap. We have been able to achieve a watertight seal of dura in multiple layers, provide adequate support to the cranial base while giving a non bulky reconstruction of the orbit.
Description
Date
2011-07
Publisher
Keywords
Type
Article
Citation
The use of a combined radial forearm flap and radial fascial flap for layered dural lining and an orbital defect reconstruction. 2011, 64 (7):e167-9 J Plast Reconstr Aesthet Surg
Journal Title
Journal ISSN
Volume Title
Embedded videos