Loading...
Thumbnail Image
Publication

Dosimetric comparison of five different techniques for craniospinal irradiation across 15 European centers: analysis on behalf of the SIOP-E-BTG (radiotherapy working group).

Seravalli, E
Bosman, M
Lassen-Ramshad, Y
Vestergaard, A
Oldenburger, F
Visser, J
Koutsouveli, E
Paraskevopoulou, C
Horan, G
Ajithkumar, T
... show 10 more
Citations
Altmetric:
Abstract
Conventional techniques (3D-CRT) for craniospinal irradiation (CSI) are still widely used. Modern techniques (IMRT, VMAT, TomoTherapy®, proton pencil beam scanning [PBS]) are applied in a limited number of centers. For a 14-year-old patient, we aimed to compare dose distributions of five CSI techniques applied across Europe and generated according to the participating institute protocols, therefore representing daily practice.