Loading...
Radiomic features from diffusion-weighted MRI of retroperitoneal soft-tissue sarcomas are eepeatable and exhibit change after radiotherapy
Thrussell, I. ; Winfield, J. M. ; Orton, M. R. ; Miah, A. B. ; Zaidi, S. H. ; Arthur, A. ; Thway, K. ; Strauss, D. C. ; Collins, D. J. ; Koh, D. M. ... show 5 more
Thrussell, I.
Winfield, J. M.
Orton, M. R.
Miah, A. B.
Zaidi, S. H.
Arthur, A.
Thway, K.
Strauss, D. C.
Collins, D. J.
Koh, D. M.
Citations
Altmetric:
Abstract
Background: Size-based assessments are inaccurate indicators of tumor response in soft-tissue sarcoma (STS), motivating the requirement for new response imaging biomarkers for this rare and heterogeneous disease. In this study, we assess the test-retest repeatability of radiomic features from MR diffusion-weighted imaging (DWI) and derived maps of apparent diffusion coefficient (ADC) in retroperitoneal STS and compare baseline repeatability with changes in radiomic features following radiotherapy (RT).
Materials and methods: Thirty patients with retroperitoneal STS received an MR examination prior to treatment, of whom 23/30 were investigated in our repeatability analysis having received repeat baseline examinations and 14/30 patients were investigated in our post-treatment analysis having received an MR examination after completing pre-operative RT. One hundred and seven radiomic features were extracted from the full manually delineated tumor region using PyRadiomics. Test-retest repeatability was assessed using an intraclass correlation coefficient (baseline ICC), and post-radiotherapy variance analysis (post-RT-IMS) was used to compare the change in radiomic feature value to baseline repeatability.
Results: For the ADC maps and DWI images, 101 and 102 features demonstrated good baseline repeatability (baseline ICC > 0.85), respectively. Forty-three and 2 features demonstrated both good baseline repeatability and a high post-RT-IMS (>0.85), respectively. Pearson correlation between the baseline ICC and post-RT-IMS was weak (0.432 and 0.133, respectively).
Conclusions: The ADC-based radiomic analysis shows better test-retest repeatability compared with features derived from DWI images in STS, and some of these features are sensitive to post-treatment change. However, good repeatability at baseline does not imply sensitivity to post-treatment change.
Description
Date
2022
Publisher
Collections
Files
Keywords
Type
Article
Citation
Thrussell I, Winfield JM, Orton MR, Miah AB, Zaidi SH, Arthur A, et al. Radiomic Features From Diffusion-Weighted MRI of Retroperitoneal Soft-Tissue Sarcomas Are Repeatable and Exhibit Change After Radiotherapy. Frontiers in oncology. 2022;12:899180. PubMed PMID: 35924167. Pubmed Central PMCID: PMC9343063. Epub 2022/08/05. eng.