The microcolony assay technique has been used to test the validty of summing equivalent doses per fraction of 14 MeV neutrons and gamma rays for mouse intestinal damage. For a 4-daily fraction schedule, in which the first one or two fractions are given as neutrons and the remainder as gamma rays, combined dose fractions calculated from a 4-fraction schedule of either radiation type alone produce the same level of damage within the limits of accuracy of the experiment.
Authors
Affiliation
Description
Date
1976-11
Publisher
Collections
Keywords
Type
Article
Citation
Addition of neutron and gamma-ray fractions for intestinal damage. 1976, 121 (2):483-6 Radiology